Download  Print this page

List Of Fault Displays - Mitsubishi Electric FR-F820-00046 Instruction Manual

Fr-f800 series.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660

Advertisement

6.4

List of fault displays

If the displayed message does not correspond to any of the
following or if you have any other problem, contact your sales
representative.
 Error message
• A message regarding operational fault and setting fault
by the operation panel and the parameter unit is
displayed. The inverter output is not shut off.
Operation panel
indication
Operation panel lock
Password locked
to
Parameter write error
to
Copy operation fault
to
Error
 Warning
• The inverter output is not shut off even when a warning is
displayed. However, failure to take appropriate measures
will lead to a fault.
Operation panel
indication
Stall prevention (overcurrent)
Stall prevention (overvoltage)
Electronic thermal relay function
pre-alarm
PU stop
Parameter copy
Safety stop
to
Maintenance signal output
USB host error
Emergency drive in operation
Continuous operation during
communication fault
Load fault warning
566
6. PROTECTIVE FUNCTIONS
6.4 List of fault displays
Refer
Name
to page
568
568
568,
569
569,
570
570
Refer
Name
to page
571
571
571
572
572
572
572
572
573
573
573
 Alarm
• The inverter output is not shut off. An Alarm (LF) signal
can also be output with a parameter setting.
Operation panel
indication
Fan alarm
Internal fan alarm
 Fault
• When a protective function is activated, the inverter
output is shut off and a Fault (ALM) signal is output.
• The data code is used for checking the fault detail via
communication or with Pr.997 Fault initiation.
 Data code 16 to 199
Operation panel
indication
Overcurrent trip during
acceleration
Overcurrent trip during
constant speed
Overcurrent trip during
deceleration or stop
Regenerative overvoltage
trip during acceleration
Regenerative overvoltage
trip during constant speed
Regenerative overvoltage
trip during deceleration or
Inverter overload trip
(electronic thermal relay
Motor overload trip
(electronic thermal relay
Heatsink overheat
Instantaneous power
failure
Undervoltage
Input phase loss
Stall prevention stop
Loss of synchronism
detection
Upper limit fault detection
Lower limit fault detection
Internal circuit fault
Output side earth (ground)
fault overcurrent
Output phase loss
Refer
Name
to page
573
573
Data
Refer
Name
code
to page
16
574
(H10)
17
574
(H11)
18
575
(H12)
32
575
(H20)
33
575
(H21)
34
576
(H22)
48
576
(H30)
49
576
(H31)
64
576
(H40)
80
577
(H50)
81
577
(H51)
82
577
(H52)
96
578
(H60)
97
578
(H61)
98
578
(H62)
99
578
(H63)
112
582
(H70)
128
579
(H80)
129
579
(H81)

Advertisement

Table of Contents

Comments to this Manuals

Symbols: 0