5.10

(C) Motor constant parameters

Purpose
To select the motor to be used
To maximize the performance of the
induction motor
To maximize the performance of the
PM motor
To perform high accuracy operation
without being affected by temperature
and high-torque/ultra-low speed
5.10.1 Applied motor
By setting the applied motor type, the thermal characteristic appropriate for the motor can be selected.
When using a constant-torque or PM motor, the electronic thermal O/L relay function is set according to the motor.
When the Advanced magnetic flux vector control or PM motor control is selected, the motor constant necessary for control (SF-
PR, SF-JR, SF-HR, SF-JRCA, SF-HRCA, MM-EFS, MM-THE4, etc.) is also selected at the same time.
Pr.
Name
71
Applied motor
C100
450
Second applied motor
C200
362
5. PARAMETERS
5.10 (C) Motor constant parameters
Applied motor
P.C100, P.C200
P.C000, P.C100 to
P.C105, P.C107,
P.C108, P.C110,
P.C120 to P.C126,
Offline auto tuning
P.C200 to P.C205,
P.C207, P.C208,
P.C210, P.C220 to
P.C226
P.C000, P.C100 to
P.C108, P.C110,
P.C120, P.C122,
P.C123, P.C126,
P.C130 to P.C133,
P.C135, P.C150,
PM motor offline auto
P.C182, P.C185,
tuning
P.C200 to P.C208,
P.C210, P.C220,
P.C222, P.C223,
P.C226, P.C230 to
P.C233, P.C235,
P.C282, P.C285
Online auto tuning
P.C111, P.C211
Initial value
Setting range
0 to 6, 13 to 16, 20, 23, 24, 40,
43, 44, 50, 53, 54, 70, 73, 74,
0
210, 213, 214, 240, 243, 244,
8090, 8093, 8094, 9090, 9093,
9094
0, 1, 3 to 6, 13 to 16, 20, 23, 24,
40, 43, 44, 50, 53, 54, 70, 73, 74,
210, 213, 214, 240, 243, 244,
9999
8090, 8093, 8094, 9090, 9093,
9094
9999
Parameter to set
Pr.71, Pr.450
Pr.9, Pr.51, Pr.71,
Pr.80 to Pr.84, Pr.90 to
Pr.94, Pr.96, Pr.453 to
Pr.463, Pr.684, Pr.707,
Pr.724, Pr.744, Pr.745,
Pr.859, Pr.860
Pr.9, Pr.51, Pr.71,
Pr.80, Pr.81, Pr.83,
Pr.84, Pr.90, Pr.92,
Pr.93, Pr.96, Pr.450,
Pr.453, Pr.454, Pr.456
to Pr.458, Pr.460,
Pr.461, Pr.463, Pr.684,
Pr.702, Pr.706, Pr.707,
Pr.711, Pr.712, Pr.717,
Pr.721, Pr.724, Pr.725,
Pr.738 to Pr.747,
Pr.788, Pr.859, Pr.860,
Pr.1002, Pr.1412,
Pr.1413
Pr.95, Pr.574
By selecting a motor, the thermal characteristic
and motor constant of each motor are set.
Set this parameter when using the second motor
(the same specifications as Pr.71).
The function is disabled.
Refer to page
362
366
375
382
Description