Mitsubishi Electric FR-F820-00046 Instruction Manual page 509

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

Pr.
Register
42125
C45 (935)
43935
1000 to
45000 to
1999
45999
• Fault history
Register
40501
40502
40503
40504
40505
40506
40507
40508
• Product profile
Register
44001
44002
44003
44004
44005
44006
44007
44008
44009
44010
44011
44012
44013
NOTE
• When a 32-bit parameter setting or monitor item is read and the value to be read exceeds HFFFF, HFFFF is returned.
 Pr.343 Communication error count
• The communication error occurrence count can be checked.
Parameter
343
NOTE
• The communication error count is temporarily stored in the RAM memory. The value is not stored in EEPROM, and so is
cleared to 0 when power is reset and the inverter is reset.
508
5. PARAMETERS
5.12 (N) Communication operation parameters
Name
PID display gain analog value
PID display gain analog value (terminal
analog value)
For details on parameter names, refer to
the parameter list
(page
132).
Definition
Fault record 1
Fault record 2
Fault record 3
Fault record 4
Fault record 5
Fault record 6
Fault record 7
Fault record 8
Definition
Model (1st and 2nd characters)
Model (3rd and 4th characters)
Model (5th and 6th characters)
Model (7th and 8th characters)
Model (9th and 10th characters)
Model (11th and 12th characters)
Model (13th and 14th characters)
Model (15th and 16th characters)
Model (17th and 18th characters)
Model (19th and 20th characters)
Capacity (1st and 2nd characters) Read
Capacity (3rd and 4th characters)
Capacity (5th and 6th characters)
Setting range
(Read-only)
Read/write
Read/write
Analog value (%) set in C45 (935)
Analog value (%) of the current (voltage) applied to
Read
terminal 4
The parameter number + 44000 is the register
Read/write
number.
Read/write
Read/write
Read
Being 2 bytes in length, the data is stored as H00○○.
Read
Refer to the lowest 1 byte for the error code. (For details on
Read
error codes, refer to
Read
The fault history is cleared by writing to register 40501.
Read
Set any value as data.
Read
Read
Read/write
Read
Read
Read
Read
The inverter model can be read in ASCII code.
Read
"H20" (blank code) is set for blank area.
Example) FR-F840-1 (FM type):
Read
H46, H52, H2D, H46, H38, H34, H30, H2D, H31, H20......H20
Read
Read
Read
Read
The capacity in the inverter model can be read in ASCII code.
Data is read in increments of 0.1 kW, and rounds down to 0.01
Read
kW increments.
"H20" (blank code) is set for blank area.
Read
Example) 0.75K: "
Minimum setting range
1
Remarks
Remarks
page
566.)
Remarks
7" (H20, H20, H20, H20, H20, H37)
Initial value
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents