Mitsubishi Electric FR-F820-00046 Instruction Manual page 150

Fr-f800 series
Hide thumbs Also See for FR-F820-00046:
Table of Contents

Advertisement

Pr.
Function
Pr.
group
820
G211
Speed control P gain 1
821
G212
Speed control integral time 1 0 to 20 s
822
T003
Speed setting filter 1
Torque control P gain 1
824
G213
(current loop proportional
gain)
Torque control integral time 1
825
G214
(current loop integral time)
827
G216
Torque detection filter 1
828
G224
Parameter for manufacturer setting. Do not set.
830
G311
Speed control P gain 2
831
G312
Speed control integral time 2 0 to 20 s, 9999
832
T005
Speed setting filter 2
Torque control P gain 2
834
G313
(current loop proportional
gain)
Torque control integral time 2
835
G314
(current loop integral time)
837
G316
Torque detection filter 2
Analog input offset
849
T007
adjustment
Terminal 4 function
858
T040
assignment
Torque current/Rated PM
859
C126
motor current
Second motor torque current/
860
C226
Rated PM motor current
864
M470
Torque detection
866
M042
Torque monitoring reference 0 to 400%
867
M321
AM output filter
Terminal 1 function
868
T010
assignment
869
M334
Current output filter
870
M440
Speed detection hysteresis
Input phase loss protection
*14
H201
872
selection
874
H730
OLT level setting
Regeneration avoidance
882
G120
operation selection
Regeneration avoidance
883
G121
operation level
Regeneration avoidance at
884
G122
deceleration detection
sensitivity
Regeneration avoidance
885
G123
compensation frequency
limit value
Regeneration avoidance
886
G124
voltage gain
888
E420
Free parameter 1
889
E421
Free parameter 2
Name
Setting range
0 to 1000%
0 to 5 s, 9999
0 to 500%
0 to 500 ms
0 to 0.1 s
0 to 1000%, 9999
0 to 5 s, 9999
0 to 500%, 9999
0 to 500 ms, 9999
0 to 0.1 s, 9999
0 to 200%
0, 4, 9999
0 to 500 A, 9999
0 to 3600 A, 9999
0 to 500 A, 9999
0 to 3600 A, 9999
0 to 400%
0 to 5 s
0, 4, 9999
0 to 5 s
0 to 5 Hz
0, 1
0 to 400%
0 to 2
300 to 1200 V
0 to 5
0 to 590 Hz, 9999
0 to 200%
0 to 9999
0 to 9999
Minimum
Initial value
setting
FM
CA
increments
1%
25%
0.001 s
0.333 s
0.001 s
9999
1%
50%
0.1 ms
40 ms
0.001 s
0 s
1%
9999
0.001 s
9999
0.001 s
9999
1%
9999
0.1 ms
9999
0.001 s
9999
0.1%
100%
1
0
*2
*2
0.01 A
9999
*3
*3
0.1 A
*2
*2
0.01 A
9999
*3
*3
0.1 A
0.1%
150%
0.1%
150%
0.01 s
0.01 s
1
0
0.01 s
0.02 s
0.01 Hz
0 Hz
1
0
0.1%
120% 110%
1
0
*7
380 VDC
0.1 V
*8
760 VDC
1
0
0.01 Hz
6 Hz
0.1%
100%
1
9999
1
9999
Refer
Customer
1
to page
setting
182
182
337
2
182
3
182
185
4
182
182
337
5
182
182
6
185
337
7
273,
334
366,
375
8
366,
375
323
9
297
10
302
273,
334
302
319
260
273
545
545
545
545
545
200
200
149
5. PARAMETERS
5.1 Parameter list

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents