Panasonic FP-E Programming Manual page 871

Fp series
Table of Contents

Advertisement

FPΣ/FP−X/FP0R
Converts 32−bit data (H00000123 and H0089ABCD) to hexadecimal ASCII codes (Normal direction)
DT10、11 = H 123
DT12、13 = H 89ABCD
When No. of converted data is "2", Starting position for storing is "0", Size of the area for storing is "6".
R0
( DF )
For the reverse direction (when "32+H" is "32−H")
Flag conditions
Σ Error flag (R9007):
Σ Error flag (R9008):
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
M
F250 BTOA,
F251 ATOB,
32+H,
D−16, DT 10, DT20, DT100
Turns on and stays on when
Turns on for an instant when
− There is an error in the control string specified by S1.
− The direction of converted data is changed to the normal direction when the
conversion format specified by S1 is in decimal.
− The size of the area for storing ASCII codes specified by N exceeds the
rated value when the conversion format specified by S1 is in hexadecimal.
(Rated value for 16−bit data: 4) (Rated value for 32−bit data: 8)
− The No. of the converted data specified by N is 0.
− The converted result exceeds the area for storing ASCII codes specified by N.
− The converted result exceeds the area.
− The area specified using the index modifier exceeds the limit.
"230100CDAB89"
DT10 , H 206 , DT 100
High−level Instructions
3 − 607

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp0Fp2Fp2shFp0rFrsFp10sh ... Show all

Table of Contents