5.1.13 Table of System Registers for FP-X

Add-
Item
ress
5
6
7
Hold/
Non-
8
hold 1
14
4
10
Hold/
11
Non-
hold 2
12
13
20
23
26
Action
on
error
4
31
32
Time
set-
34
ting
36
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
Starting number setting for
counter
Hold type area starting number
setting for timer and counter
Hold type area starting number
setting for internal relays
Hold type area starting number
setting for data registers
Hold or non-hold setting for step
ladder process
Previous value is held for a
leading edge detection instruction
(DF instruction) with MC
Hold type area starting number for
PC(PLC) W0-0 link relays
Hold type area starting number for
PC(PLC) W0-1 link relays
Hold type area starting number for
PC(PLC) W0-0 link registers
Hold type area starting number for
PC(PLC) W0-1 link registers
Disable or enable setting for
duplicated output
Operation setting when an I/O
verification error occurs
Operation setting when an
operation error occurs
Alarm battery error
(Operating setting when
battery error occurs)
Wait time setting for multi-frame
communication
Timeout setting for SEND/RECV,
RMRD/RMWT commands
Constant value settings for scan
time
Expansion unit recognition time
Default
value
1008
0 to 1024
0 to 1024
1008
248
0 to 256
C14: 12230
C30, C60:
0 to 32765
32710
Hold/
Non-hold
Non-hold
Hold/
Hold
Non-hold
64
0 to 64
128
64 to 128
128
0 to 128
256
128 to 256
Disabled
Disabled/Enabled
Stop
Stop/Continuation of operation
Stop
Stop/Continuation of operation
Dis-
abled:
Disabled
Ena-
bled:
6500.0 ms
10 to 81900 ms
10000.0 ms
10 to 81900 ms
0: Normal scan
Normal
0 to 350 ms: Scans once each
scan
specified time interval
0
(No wait
0 to 10 s (0.1 second bit)
time)
Description
• These settings
are effective if the
optional backup
battery is
installed.
• If no backup
battery is used, do
not change the
default settings.
Otherwise proper
functioning of
hold/non-hold
values cannot be
guaranteed.
When a battery error
occurs, a self-diagnostic
error is not issued and
the ERROR/ALARM
LED does not flash.
When a battery error
occurs, a self-diagnostic
error is issued and the
ERROR/ALARM LED
flashes.
5-107