No.
400
High-
speed
coun-
ter
401
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
High-speed counter
operation mode
settings (X0 to X2)
High-speed counter
operation mode
settings (X3 to X5)
Default
value
Do not set input X0 as high-speed counter.
Two-phase input (X0, X1)
Two-phase input (X0, X1), Reset input (X2)
Incremental input (X0)
CH0:
Incremental input (X0), Reset input (X2)
Do not set
Decremental input (X0)
input X0
Decremental input (X0), Reset input (X2)
CH0
incremental/decremental input (X0, X1)
as high-
incremental/decremental input (X0, X1),
speed
Reset input (X2)
counter
Incremental/decremental control input (X0,
X1)
Incremental/decremental control input (X0,
X1), Reset input (X2)
CH1:
Do not set input X1 as high-speed counter.
Do not set
Incremental input (X1)
input X1
CH1
Incremental inptu (X1), Reset input (X2)
as high-
Decremental input (X1)
speed
Decremental input (X1), Reset input (X2)
counter
Do not set input X3 as high-speed counter.
Two-phase input (X3, X4)
Two-phase input (X3, X4), Reset input (X5)
Incremental input (X3)
CH2:
Incremental input (X3), Reset input (X5)
Do not set
Decremental input (X3)
input X3
Decremental input (X3), Reset input (X5)
CH2
Incremental/decremental input (X3, X4)
as high-
Incremental/decremental input (X3, X4),
speed
Reset input (X5)
counter
Incremental/decremental control input
(X3, X4)
Incremental/decremental control input
(X3, X4), Reset input (X5)
HC3:
Do not set input X4 as high-speed counter.
Do not set
Incremental input (X4)
input X4
CH3
Incremental input (X4), Reset input (X5)
as high-
Decremental input (X4)
speed
Decremental input (X4), Reset input (X5)
counter
Descriptions