Panasonic FP-E Programming Manual page 1243

Fp series
Table of Contents

Advertisement

MEWNET-W PC link setting
For PC link (W) 0: System register 40 to 45
For PC link (W) 1: System register 50 to 55
Regarding the link relays and link data registers, specify the range for communication and divide it up for
sending and receiving.
The default settings have the range for communication (system register 40, 41, 50 and 51) set to 0 so
that PC link communication is not possible.
If the range for sending (system register 43, 45, 53 and 55) is set to 0, the range for communication will
all be for receiving.
The link relay and link data register ranges not used for communication, can each be used as internal
relays and data registers.
5-155