High−level Instructions
Specifying the various items
Control data (S1)
Specifying the remote station
Specify the remote station by means of a route number and unit number.
The setting is entered differently depending on whether the remote station is a PLC in the same network, or a
PLC in a network on a different hierarchical level.
Specifying the transmission unit and transmission method
If data is to be received in word units, specify the data volume, and if it is to be received in bit units, specify the
position of the target bit.
Specifying the memory area of the remote station (S2) and (N)
Specify the memory area of the remote station in which the data being received is to be stored, specifying the
type S2 and the address N in combination.
Example:
S2: DT10, N: K100
Specifying the memory area of the local station (D)
Specify the memory area of the local station in which the data received from the remote station is to be stored.
Flag conditions
Σ Error flag (R9007):
Σ Error flag (R9008):
Receiving from a PLC within the same network
Specifying the control data (S1+1, S1)
The control data should be specified as an H constant. The transmission unit, transmission method and other
parameters are specified with S1, and the remote station is specified with S1+1.
S1+1
Specifying the
remote station
3 − 378
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
DT100
Turns on and stays on when:
Turns on for an instant when:
− The control data is a value outside of the specified range.
− Tthe remote station does not exist.
− The number of words specified by S1 causes the area of S2 or D to be
exceeded when word unit reception is being used.
S1
Specifying the
transmission unit and
method