Panasonic FP-E Programming Manual page 1315

Fp series
Table of Contents

Advertisement

Num-
Name
ber
F347
Floating-point
P347
type data
upper and
lower limit
control
F348
Floating-point
P348
type data
dead-band
control
F349
Floating-point
P349
type data
zone control
F350
Floating-point
P350
type data
maxi-mum
value
F351
Floating-point
P351
type data
mini-mum
value
F352
Floating-point
P352
type data total
and mean
values
F353
Floating-point
P353
type data sort
F354
Scaling of
P354
real number
data
: Available,
: Not available,
*1) This instruction is available for FP2/FP2SH Ver. 1.5 or later. FP10SH cannot be used.
*2) This instruction is available for FPΣ 32k type.
*3) This instruction is available for FP-X Ver. 1.13 or later.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Ope-
Boolean
rand
FLIMT
S1, S2,
When (S1+1, S1)>(S3+1, S3),
(S1+1, S1) →(D+1, D)
PFLIMT
S3, D
When (S2+1, S2)<(S3+1, S3),
(S2+1, S2) → (D+1, D)
When (S1+1, S1)<or = (S3+1,
S3)<or =(S2+1, S2), (S3+1,
S3)→(D+1, D)
FBAND
S1, S2,
When (S1+1, S1)>(S3+1, S3),
PFBAND
S3, D
(S3+1, S3)−(S1+1, S1)→(D+1, D)
When (S2+1, S2)<(S3+1, S3),
(S3+1, S3)−(S2+1, S2)→ (D+1, D)
When (S1+1, S1)<or = (S3+1,
S3)<or =(S2+1, S2), 0.0→(D+1, D)
FZONE
S1, S2,
When (S3+1, S3)<0.0,
PFZONE
S3, D
(S3+1, S3)+(S1+1, S1)→(D+1, D)
When (S3+1, S3)=0.0, 0.0→ (D+1,
D)
When (S3+1, S3)>0.0, (S3+1,
S3)+(S2+1, S2) →(D+1, D)
FMAX
S1, S2,
Searches the maximum value in the
PFMAX
D
real number data table between the
area selected with "S1" and "S2",
and stores it in the (D+1, D). The
address relative to "S1" is stored in
(D+2).
FMIN
S1, S2,
Searches the minimum value in the
PFMIN
D
real number data table between the
area selected with "S1" and "S2",
and stores it in the (D+1, D). The
address relative to "S1" is stored in
(D+2).
FMEAN
S1, S2,
The total value and the mean value
PFMEAN
D
of the real number data from the
area selected with "S1" to "S2" are
obtained. The total value is stored in
the (D+1, D) and the mean value is
stored in the (D+3, D+2).
FSORT
S1, S2,
The real number data from the area
PFSORT
S3
speciified by "S1" to "S2" are stored
in ascending order (the smallest
word is first) or descending order
(the largest word is first).
FSCAL
S1, S2,
Scaling (linearization) on a real
PFSCAL
D
number data table is performed, and
the output (Y) to an input value (X)
is calculated.
: Not available partially
Description
17
17
17
12
8
8
8
8
*2
*3
*1
5-227
*1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp0Fp2Fp2shFp0rFrsFp10sh ... Show all

Table of Contents