Panasonic FP-E Programming Manual page 1176

Fp series
Table of Contents

Advertisement

WR904
Relay No.
TOOL port operation
R9040
mode flag
R9041
COM1 port PLC link flag
COM2 port
R9042
communication mode
flag
R9043
Not used
COM1 port SEND/RECV
R9044
instruction execution
flag
COM1 port SEND/RECV
R9045
instruction execution
end flag
R9046
Not used
COM2 port
R9047
communication error
flag
COM2 port port
reception done flag
R9048
during general-purpose
communicating
COM2 port transmission
done flag during
R9049
general-purpose
communication
COM2 port SEND/RECV
R904A
instruction execution
flag
COM2 port SEND/RECV
R904B
instruction execution
end flag
R904C to
Not used
R904D
Circular interpolation
R904E
control flag
Circular interpolation
R904F
data overwrite
confirmation flag
Note) R9040 to R904F can be changed during 1 scan.
WR905
Relay No.
MEWNET-W0
R9050
PLC link transmission
error flag
R9051 to
Not used
R905F
5-88
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
Turns on when the general-purpose communication
-
function is being used
Goes off when the computer link function is being used.
-
Turn on while the PLC link function is used.
Goes on when the general-purpose serial communication
-
is used.
Goes off when the MEWTOCOL is used.
-
-
Monitors whether the F145 (SEND) or F146 (RECV)
instructions can be executed or not.
Off: None of the above mentioned instructions can be
On: One of the above mentioned instructions can be
Monitors if an abnormality has been detected during the
execution of the F145 (SEND) or F146 (RECV)
instructions as follows:
Off: No abonormality detected.
On: An abnormality detected. (communication error)
The error code is stored in DT90039.
End code: DT90124
-
Goes on if a transmission error occurs during data
-
communication.
Goes off when a request is made to send data, using the
-
F159 (MTRN) instruction.
Turn on when the terminator is received during general-
-
purpose serial communication.
Goes on when transmission has been completed in
-
general-purpose serial communication.
Goes off when transmission is requested in general-
-
purpose communication.
Monitors whether the F145 (SEND) or F146 (RECV)
instructions can be executed or not.
Off: None of the above mentioned instructions can be
On: One of the above mentioned instructions can be
Monitors if an abnormality has been detected during the
execution of the F145 (SEND) or F146 (RECV)
instructions as follows:
Off: No abonormality detected.
On: An abnormality detected. (communication error)
The error code is stored in DT90039.
End code: DT90125
-
Goes on when the F176 (SPCH) circular interpolation
instruction is executed.
It is used to overwrite next data when the circular
interpolation instruction is used in the continuation mode.
Name
When using MEWNET-W0
Turns on when a transmission error occurs at PLC link.
-
Turns on when there is an error in the PLC link area
-
settings.
Description
executed. (During executing the instruction)
executed.
executed. (During executing the instruction)
executed.
Description