High−level Instructions
When Lower limit S1+1 and S1
and S3 stored in D+1 and D as the output value.
Output value D+1 and D
[S2+1, S2]
Lower limit S1+1 and S1
Specifying the integer device with [S1], [S2] and [S3], the integer data is internally converted to real numbers
before operations continue.
R0
F347 FLIMT, % DT10, % DT20, DT30, DT40
Specifying the integer device with [D], the real numbers are automatically converted into integer data.
R0
F347 FLIMT, DT10, DT20, DT30, % DT40
When the constant K is specified in S1, S2 and S3, the operations are the same as when a integer device is
specified.
Flag conditions
・Error flag (R9007):
・Error flag (R9008):
・= flag (R900B):
3 − 746
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Input value S3+1 and S3
Input value S3+1 and S3
Upper limit S2+1 and S2
[S1+1, S1]
Turns on and stays on when:
Turns on for an instant when:
− The area specified using the index modifier exceeds the limit.
− If data other than real number data is specified in (S1+1 and S1), (S2+1
and S2) and (S3+1 and S3).
− (S1+1, S1) > (S2+1, S2).
− If result of operating is outside integer range when integer device is
specified in D+1 and D.
Turns on when result of operating is within the range of the upper and lower
limits.
Upper limit S2+1 and S2, the input value S3+1