No.
410
Unit No. setting
Communication
mode setting
412
Selection of modem
connection
Communication
413
format setting
Tool
port
set-
ting
Communication
415
speed (Baud rate)
setting
Starting address for
received buffer of
420
general (serial data)
communication mode
Buffer capacity
setting for data
421
received of general
(serial data)
communication mode
410
Unit No. setting
Communication
mode setting
412
Selection of modem
connection
Communication
413
format setting
COM
port
set-
ting
Communication
415
speed (Baud rate)
setting
Starting address for
received buffer of
416
general (serial data)
communication mode
Buffer capacity
setting for data
417
received of general
(serial data)
communication mode
Note1) The communication format in a PLC link is fixed at the following settings:
Data length is 8 bits, odd parity, stop bit is 1.
The communication speed (baud rate) is fixed at 115200 bps.
Note2) The general-purpose communication with the tool port is available only in RUN mode. In PROG
mode, the computer link mode must be used regardless of settings.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Default
Name
value
1
Computer link
Disabled
Data lenght
bit: 8 bits
Parity check:
"with odd"
Stop bit: 1 bit
9600 bps
4096
2048
1
Computer link
Disabled
Data lenght
bit: 8 bits
Parity check:
Odd
Stop bit: 1 bit
9600 bps
0
2048
Descriptions
1 to 99
Computer link
General-purpose communications
Enabled/Disabled
Enter the settings for the various items.
Data lenght bit: 7 bits/8 bits
-
Parity check: none/with odd/with even
-
Stop bit: 1 bit/2 bits
-
The following setting is valid only when
-
the communication mode specified by
system register 412 has been set to
"General-purpose serial communication".
Terminator CR/CR+LF/None
-
Header: STX not exist/STX exist
-
2400 bps / 4800 bps / 9600 bps /
19200 bps / 38400 bps / 57600 bps /
115200 bps
0 to 32764
0 to 2048
1 to 99
Computer link
General-purpose serial communication
PC(PLC) link
MODBUS RTU
Enabled/Disabled
Enter the settings for the various items.
Data lenght bit: 7 bits/8 bits
-
Parity check: none/with odd/with even
-
Stop bit: 1 bit/2 bits
-
The following setting is valid only when
-
the communication mode specified by
system register 412 has been set to
"General-purpose serial communication".
Terminator CR/CR+LF/None/ETX
-
Header: STX not exist/STX exist
-
2400 bps / 4800 bps / 9600 bps /
19200 bps / 38400 bps / 57600 bps /
115200 bps
0 to 32764
0 to 2048
FP0R