Panasonic FP-E Programming Manual page 900

Fp series
Table of Contents

Advertisement

High−level Instructions
Precaution during programming
Even if D+1 overflows the selected area, it will still be stored, and this may corrupt the data in the leading part
of the other area. (An area overflow check is not performed.)
Flag conditions
・Error flag (R9007):
・Error flag (R9008):
3 − 636
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Turns on and stays on when:
Turns on for an instant when:
− The area specified using the index modifier exceeds the limit.
− S1 > S2.
− The areas of S1 and S2 are different.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp0Fp2Fp2shFp0rFrsFp10sh ... Show all

Table of Contents