High−level Instructions
Preparation for reception
Setting of COM 1 port reception buffer
The area of data registers DT0 up to DT2047 is the default reception buffer.
The maximum number of bytes that can be received is 4094 bytes.
Specify start area as
No. 416.
Setting of COM 2 port reception buffer
(This setting is not available for the FP0R.)
The area of data registers DT2048 up to DT4095 is the default reception buffer.
The maximum number of bytes that can be received is 4094 bytes.
Specify start area as
No. 418.
Setting of Tool port reception buffer
The area of data registers DT4096 up to DT6143 is the default reception buffer.
The maximum number of bytes that can be received is 4094 bytes.
Specify start area as
No. 420.
3 − 424
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
No. 416 and No. 417
No. of received
bytes
Specified number of
words for No. 417
Reception
data
storage
area
No. 418 and No. 419
No. of received
bytes
Specified number of
words for No. 419
Reception
data
storage
area
No. 420 and No. 421
No. of received
bytes
Specified number of
words for No. 421
Reception
data
storage
area