Panasonic FP-E Programming Manual page 1096

Fp series
Table of Contents

Advertisement

FP0
Add-
Item
ress
Wait time setting for
31
multi-frame
communication
Time
setting
Constant value settings
34
for scan time
High-speed
counter
Input
400
mode
setting
settings
(X0 to X2)
Note1) If the operation mode is set to 2-phase, individual, or direction differentiation, the setting for CH1
is invalid.
Note2) If reset input settings overlap, the setting of CH1 takes precedence.
Note3) If system register 400 to 403 have been set simultaneously for the same input relay, the following
precedence order is effective: [High-speed counter] '[Pulse catch]' [Interrupt input].
5-8
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Default
Name
value
6500 ms
(K2600)
0 ms
(K0)
Do not set
X0 as
high-
speed
Setting by
counter.
progra-
mming tool
software
Do not set
X1 as
high-
speed
counter.
Descriptions
10 ms to 81900 ms (K4 to K32760)
Used of default setting (K2600/6500
ms) is recommended.
2.5 ms to 160 ms (K1 to K64 ): Scans
once each specified time interval.
0 (K0):Normal scan
Do not set X0 as high-speed
counter.
2-phase input (X0, X1)
2-phase input (X0, X1),
Reset input (X2)
Incremental input (X0)
Incremental input (X0), Reset input
(X2)
CH0
Decremental input (X0)
Decremental input (X0),
Reset input (X2)
Individual input (X0, X1)
Individual input (X0, X1),
Reset input (X2)
Direction decision (X0, X1)
Direction decision (X0, X1),
Reset input (X2)
Do not set X1 as high-speed
counter.
Incremental input (X1)
Incremental input (X1), Reset input
CH1
(X2)
Decremental input (X1)
Decremental input (X1), Reset input
(X2)