High−level Instructions
Description
The floating point data (32 bits) specified by S is copied to the 32-bit area specified by D when the trigger turns
on.
Floating point data
Real number data
DT:
D+1:
Range of real number data which can be set are as follows:
Positive: f0.0000001 to f9999999
Negative: f−9999999 to f−0.000001
Precaution during programming
For FP0, this instruction F309 (FMV) cannot be programmed in the interrupt program.
Flag conditions
・Error flag (R9007):
・Error flag (R9008):
3 − 682
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
15
Lower word
Higher word
Turns on and stays on when the area specified using the index modifier
exceeds the limit.
Turns on for an instant when the area specified using the index modifier
exceeds the limit.