Panasonic FP-E Programming Manual page 412

Fp series
Table of Contents

Advertisement

High−level Instructions
Description
Performs exclusive OR operation on each bit in the 16-bit equivalent constant or 16-bit data specified by S1
and S2. The exclusive OR operation result is stored in the 16-bit area specified by D.
{(S1)
{(S1)
(S2)}
Detects the bits whose on and off states do not match.
If the values of S1 and S2 are equal, all the bits of the data specified by D become 0.
Exclusive OR operation
The exclusive OR operation is shown below.
S1
S2
D
0
0
0
0
1
1
1
0
1
1
1
0
Flag conditions
・Error flag (R9007):
・Error flag (R9008):
・= flag (R900B):
3 − 148
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
(S2)} → (D)
Turns on and stays on when the area specified using the index modifier
exceeds the limit.
Turns on for an instant when the area specified using the index modifier
exceeds the limit.
Turns on for an instant when the calculated result is recognized as "0".

Hide quick links: