Panasonic FP-E Programming Manual page 1175

Fp series
Table of Contents

Advertisement

WR903
Relay No.
R9030
Not used
R9031
Not used
COM1 port
R9032
communication mode
flag
Print instruction
R9033
execution flag
RUN overwrite complete
R9034
flag
R9035
Not used
R9036
Not used
COM1 port
R9037
communication error
flag
COM1 port reception
R9038
done flag during general
purpose communication
COM1 port transmission
done flag during
R9039
general-purpose serial
communication
High-speed
R903A
counter control
flag
High-speed
R903B
counter control
flag
High-speed
R903C
counter control
flag
High-speed
R903D
counter control
flag
TOOL port reception
R903E
done flag during general
purpose communication
TOOL port transmission
done flag during
R903F
general-purpose serial
communication
Note) R9030 to R9030F can be changed during 1 scan.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
-
-
Turns on when the general-purpose communication
-
function is being used
Goes off when the MEWTOCOL-COM or the PLC link
-
function is being used.
Off: Printing is not executed.
On: Execution is in progress.
Goes on for ony the first scan following completion of a
rewrite during the RUN operation.
-
-
Goes on is a transmission error occurs during data
-
communication.
Goes off when a request is made to send data, using the
-
F159 (MTRN) instruction.
Turns on when the terminator is received during general -
-
purpose serial communication.
Goes on when transmission has been completed in
-
general-purpose serial communication.
Goes off when transmission is requested in general-
-
purpose serial communication.
Turn on while the high-speed counter instructions
ch0
F166(HC15), F167(HC1R) and the pulse output instructions
F171(SPDH) to F176(PWMH) are executed.
Turn on while the high-speed counter instructions
ch1
F166(HC15), F167(HC1R) and the pulse output instructions
F171(SPDH) to F176(PWMH) are executed.
Turn on while the high-speed counter instructions
ch2
F166(HC15), F167(HC1R) and the pulse output instructions
F171(SPDH) to F176(PWMH) are executed.
Turn on while the high-speed counter instructions
ch3
F166(HC15), F167(HC1R) and the pulse output instructions
F171(SPDH) to F176(PWMH) are executed.
Turns on when the terminator is received during general -
-
purpose serial communication.
Goes on when transmission has been completed in
-
general-purpose serial communication.
Goes off when transmission is requested in general-
-
purpose serial communication.
Description
5-87