High−level Instructions
Description
The output value (double word data) stored in the area specified by D is controlled based on whether or not
the input value (double word data) specified by S3 falls within the dead-band bounded by the upper and lower
limits set in S1 and S2.
The output value is determined based on the following conditions:
When the lower limit S1+1 and S1 are greater than the input value S3+1 and S3, the input value S3+1 and S3
minus the lower limit value S1+1 and S1 are stored in D+1 and D as the output value.
When the upper limit S2+1 and S2 are less than the input value S3+1 and S3, the input value S3+1 and S3
minus the upper limit value S2+1 and S2 are stored in D+1 and D as the output value.
When Lower limit S1+1 and S1
and D as the output value.
Output value D+1 and D
Lower limit of deadband
S1+1 and S1
In this range, zero is output.
Flag conditions
・Error flag (R9007):
・Error flag (R9008):
・Carry flag (R9009): Turns on for an instant when the calculated result is overflowed or
・= flag (R900B):
3 − 664
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Input value S3+1 and S3
Input value S3+1 and S3
0
Upper limit of deadband S2+1 and S2
Turns on and stays on when:
Turns on for an instant when:
− The area specified using the index modifier exceeds the limit.
− S1 > S2.
underflowed.
Turns on when the input value is recognized as "0."
Upper limit S2+1 and S2, zero is stored in D+1