5.1.14 Table of Special Internal Relays for FP-X

The special internal relays turn on and off under special conditions. The on and off states are not output
externally. Writing is not possible with a programming tool or an instruction.
WR900 FP-X
Address
Self-diagnostic error
R9000
flag
R9001
Not used
Application cassette
R9002
I/O error flag
Application cassette
R9003
abnormal error flag
I/O verification error
R9004
flag
Backup battery error
R9005
flag (non-hold)
Backup battery error
R9006
flag (hold)
Operation error flag
R9007
(hold)
Operation error flag
R9008
(non-hold)
R9009
Carry flag
R900A
> Flag
R900B
= Flag
R900C
< Flag
Auxiliary timer
R900D
Contact
Tool port
R900E
communication error
Constant scan error
R900F
flag
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
Turns on when a self-diagnostic error occurs.
⇒ The content of self-diagnostic error is stored in DT90000.
-
Turns on when an error is detected in the I/O type application
cassette.
Turns on when an error is detected in the application cassette.
Turns on when an I/O verification error occurs.
Turns on when a backup battery error occurs.
Turns on when the battery has run out even if the system
register No. 4 has been set not to inform the battery error.
Turns on when a backup battery error occurs.
Turns on when the battery has run out even if the system
register No. 4 has been set not to inform the battery error.
Once a battery error has been detected, this is held even after
recovery has been made.
⇒It goes off if the power supply is turned off, or if the system
is initialized.
Turns on and keeps the on state when an operation error
occurs.
⇒The address where the error occurred is stored in DT90017.
(indicates the first operation error which occurred).
Turns on for an instant when an operation error occurs.
⇒The address where the operation error occurred is stored in
DT90018. The contents change each time a new error occurs.
This is set if an overflow or underflow occurs in the calculation
results, and as a result of a shift system instruction being
executed.
Turns on for an instant when the compared results become
larger in the comparison instructions.
Turns on for an instant,
when the compared results are equal in the comparison
-
instructions.
when the calculated results become 0 in the arithmetic
-
instructions.
Turns on for an instant when the compared results become
smaller in the comparison instructions.
Turns on when the set time elapses (set value reaches 0) in
the timing operation of the F137(STMR)/F183(DSTM)
auxiliary timer instruction. The flag turns off when the trigger
for auxiliary timer instruction turns off.
Turns on when communication error at tool port is occurred.
Turns on when scan time exceeds the time specified in
system register 34 during constant scan execution.
This goes on if 0 has been set using system register 34.
Description
5-119