Panasonic FP-E Programming Manual page 1144

Fp series
Table of Contents

Advertisement

WR908 FP0R
Relay No.
R9080
R9081
R9082
R9083
R9084
R9085
R9086
MEWNET-
W0
R9087
PC(PLC)
link 1
trans-
mission
R9088
assurance
relay
R9089
R908A
R908B
R908C
R908D
R908E
R908F
A: Available, N/A: Not available
5-56
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
Turns on when Unit No. 1 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.1
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 2 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.2
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 3 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.3
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 4 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.4
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 5 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.5
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 6 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.6
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 7 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.7
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 8 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.8
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 9 is communicating properly in PC(PLC)
Unit
link mode. Turns off when operation is stopped, when an error
No.9
occurs, or when not in the PC(PLC) link mode.
Turns on when Unit No. 10 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.10
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 11 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.11
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 12 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.12
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 13 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.13
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 14 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.14
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 15 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.15
occurs, or when not in the PC(PLC) link 1 mode.
Turns on when Unit No. 16 is communicating properly in PC(PLC)
Unit
link 1 mode. Turns off when operation is stopped, when an error
No.16
occurs, or when not in the PC(PLC) link 1 mode.
Description