Panasonic FP-E Programming Manual page 741

Fp series
Table of Contents

Advertisement

FP0R
Example of target value match OFF setting
When specifying the pulse output
Condition
(1) Specify the pulse output channle number 0.
(2) Set the targe value to 10000.
(3) Set the output coil to be turned off when the values match to Y2.
R0
( DF )
F167 HC1R, H100, K10000, Y2
Execution of program
Target value
10000
0
R0
Control flag
R9130
Y2
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Pulse output control start
Elapsed value
End of F166 control (clear)
The number of the pulse output control flag varies depend-
ing on the channel used.
Regarding the channel number and control flag for each
model, refer to the table on the next page.
Targe value match OFF
High−level Instructions
3 − 477

Hide quick links: