Panasonic FP-E Programming Manual page 746

Fp series
Table of Contents

Advertisement

High−level Instructions
2: For FP0 compatibility mode
Pulses are output using a duty of 25% fixedly. (The setting is invalid.)
The pulse output will start approx. 300us later after the direction output. (The
characteristics of a motor driver is considered.)
Application example
R0
F0 MV, H 2, DT 0
F0 MV, K1000, DT 1
F0 MV, K7000, DT 2
F0 MV, K300, DT 3
F1 DMV, K100000, DT 4
F0 MV, K 0, DT 6
R1
F168 SPD1, DT 0, K 0
DT 0
H
1002
DT 1
K
1000
DT 2
K
7000
DT 3
K
300
DT 4
K100000
K100000
DT 5
DT 6
0
7kHz
1kHz
300ms
f
f = (7000 − 1000) ÷ 30 steps = 200(Hz)
t = 300ms ÷ 30 steps = 10ms
t
Flag conditions
・Error flag (R9007):
・Error flag (R9008):
3 − 482
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Number of
output pulse
100,000
300ms
Turns on and stays on when:
Turns on for an instant when:
− The area specified using the index modifier exceeds the limit.
− n is number except 0 and 1.
− The value of S exceeds the limit of specified range.
− S+1 is less than K40
− S+1 > S+2
− The value of "S+5, S+4" exceeds the limit of specified range.
FP0/FP−e