F174
Pulse output
(Selectable data
table control
operation )
F175
Pulse output
(Linear
interpolation)
F176
Pulse output
(Circular
interpolation)
F177
Pulse output
(Home return)
F178
Input pulse
measurement
(No. of pulses,
cycle for input
pulses)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Boo-lean
Operand
SP0H
S, n
Outputs the pulses from the
specified channel according to
the
data table specified by S.
SPSH
S, n
Pulses are output from channel,
in accordance with the
designated data table, so that
the path to the target position
forms a straight line.
SPCH
S, n
Pulses are output from channel,
in accordance with the
designated data table, so that
the path to the target position
forms an arc.
HOME
S, n
Performs the home return
according to the specified data
table.
PLSM
S1, S2, D
Measures the number of pulses
and cycle of pulses to be input
to the high-speed counter of the
specified channel.
Description