High−level Instructions
Explanation of program operation
When adding + subtracting elapsed values with the maximum target value and interrupt control, the operation
will be performed as below if the following conditions are met; Elapsed value when the instruction is executed:
K−4000 < Elapsed value < K4000 Internal relay R3: ON
*The operation can be started once the interrupt program is permitted to be started with ICTL instruction.
Elapsed value of high−speed counter
K8000
K4000
K−4000
K−10000
R3
R9110
R10
R11
R12
R13
R14
INT0
* The execution time in the interrupt program should be shorter than the travelling time between control positions.
Flag conditions
・Error flag (R9007):
・Error flag (R9008):
3 − 460
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
− Turns on when the area specified using the index modifier exceeds the limit.
− Turns on when the specified channel is out of the setting range.
− Turns on when any other setting than the high−speed counter/pulse output
is specified.
− Turns on when the word number of the internal relay where the target value
is output is out of the setting range.
− Turns on when the specification of the number of target values exceeds the
limit. (Up to 31)
− Turns on when the garge value is greater than the maximum target value.
− Turns on when the target value is 0.
− Turns on when the targe values are not arranged in asceding order.
− Turns on ending 16−bito area used for this instruction exceeds the limit of
data table.
− Turns on when the high−speed counter has not been set for the specified
channel by the system register.
Time
FP0R