Panasonic FP-E Programming Manual page 1262

Fp series
Table of Contents

Advertisement

FP1/FP-M/FP2/FP2SH/FP10SH/FP3
Address
R9090
R9091
R9092
R9093
R9094
R9095
R9096
MEWNET-W/-P
PC link
R9097
operation mode
relay
R9098
[for PC link 1
(W/P)]
R9099
R909A
R909B
R909C
R909D
R909E
R909F
IC memory card
installation flag
R9100
(Available PLC: FP2SH/
FP10SH)
IC memory card backup
R9101
battery flag 1
(*Note)
(Available PLC: FP2SH/
FP10SH)
IC memory card backup
R9102
battery flag 2
(*Note)
(Available PLC: FP2SH/
FP10SH)
Note) When the system registers 46=K0, PC link 0 for the link unit with a smaller slot No. and PC link 1
for one with a larger slot No.
When the system registers 46=K1, PC link 1 for the link unit with a smaller slot No. and PC link 0
for one with a larger slot No.
5-174
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
Unit
Turns on when unit No. 1 is in the RUN mode.
No.1
Turns off when unit No. 1 is in the PROG. mode.
Unit
Turns on when unit No. 2 is in the RUN mode.
No.2
Turns off when unit No. 2 is in the PROG. mode.
Unit
Turns on when unit No. 3 is in the RUN mode.
No.3
Turns off when unit No. 3 is in the PROG. mode.
Unit
Turns on when unit No. 4 is in the RUN mode.
No.4
Turns off when unit No. 4 is in the PROG. mode.
Unit
Turns on when unit No. 5 is in the RUN mode.
No.5
Turns off when unit No. 5 is in the PROG. mode.
Unit
Turns on when unit No. 6 is in the RUN mode.
No.6
Turns off when unit No. 6 is in the PROG. mode.
Unit
Turns on when unit No. 7 is in the RUN mode.
No.7
Turns off when unit No. 7 is in the PROG. mode.
Unit
Turns on when unit No. 8 is in the RUN mode.
No.8
Turns off when unit No. 8 is in the PROG. mode.
Unit
Turns on when unit No. 9 is in the RUN mode.
No.9
Turns off when unit No. 9 is in the PROG. mode.
Unit
Turns on when unit No. 10 is in the RUN mode.
No.10
Turns off when unit No. 10 is in the PROG. mode.
Unit
Turns on when unit No. 11 is in the RUN mode.
No.11
Turns off when unit No. 11 is in the PROG. mode.
Unit
Turns on when unit No. 12 is in the RUN mode.
No.12
Turns off when unit No. 12 is in the PROG. mode.
Unit
Turns on when unit No. 13 is in the RUN mode.
No.13
Turns off when unit No. 13 is in the PROG. mode.
Unit
Turns on when unit No. 14 is in the RUN mode.
No.14
Turns off when unit No. 14 is in the PROG. mode.
Unit
Turns on when unit No. 15 is in the RUN mode.
No.15
Turns off when unit No. 15 is in the PROG. mode.
Unit
Turns on when unit No. 16 is in the RUN mode.
No.16
Turns off when unit No. 16 is in the PROG. mode.
Monitors whether the IC memory card is installed or not:
- on: IC memory card is installed.
- off: IC memory card is not installed.
Monitors the voltage drop condition for the IC memory card
as:
- on: Data in the IC memory card cannot be guaranteed.
- off: Data in the IC memory card can be maintained.
Monitors the voltage drop condition for the IC memory card
as:
- on: Battery replacement is required.
- off: Battery replacement is not required.
Description