Panasonic FP-E Programming Manual page 756

Fp series
Table of Contents

Advertisement

High−level Instructions
Data table settings
S
Control code
S+1
Duty (%)
(*1): Control code contents (frequency settings)
Setting
H11
H12
H13
H14
H15
H16
H0
H1
H2
H3
H4
H5
H6
H7
H8
H11 to H16 are supported by CPU Ver. 2.0 and subsequent versions.
Flag conditions
・Error flag (R9007):
・Error flag (R9008):
3 − 492
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
H0 to H16 (*1)
K1 to K999 (0.1% to 99.9%)
FP0
Frequency (Hz)
Period (ms)
1000
1.0
714
1.4
500
2.0
400
2.5
200
5.0
100
10.0
38
26.3
19
52.6
9.5
105.3
4.8
208.3
2.4
416.7
1.2
833.3
0.6
1666.7
0.3
3333.3
0.15
6666.7
Turns on and stays on when:
Turns on for an instant when:
− The area specified using the index modifier exceeds the limit.
− n is number except 0 and 1.
− The frequency setting value set with (S) is outside the specification range.
− 100% or higher is set with (S + 1)
FP0 compatibility mode of FP0R
Frequency (Hz)
Period (ms)
1000
1.0
750
1.3
500
2.0
400
2.5
200
5.0
100
10.0
40
25.0
20
50.0
10
100.0
6
166.7
Cannot be specified
Cannot be specified
Cannot be specified
Cannot be specified
Cannot be specified
FP0/FP−e

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp0Fp2Fp2shFp0rFrsFp10sh ... Show all