Panasonic FP-E Programming Manual page 764

Fp series
Table of Contents

Advertisement

High−level Instructions
For FP−X Tr type
Channel
Control
no.
flag
ch0
ch0
R911C
R911C
ch1
ch1
R911D
R911D
ch2
ch2
R911E
R911E
ch3
ch3
R911F
R911F
Note) There is no ch3 for C14T and C14TD.
Operation modes
Return to home position
Pulses are output continually until home input (X2 or X5) occurs. To decelerate at near home, set the
corresponding bit of special data register DT90052 off → on → off when near home input occurs.
The value in the elapsed value area during a home position return differs from the current value. When the
return is completed, the elapsed value changes to 0.
Home position return by means of near home input and home input
Deceleration occurs when near home input occurs, and pulse output stops after home input. Operation
varies depending on the control code (lower order) settings described on the following page.
f
Fmax
Fmin
Home position return using only home input
Pulse output stops when home input occurs. Use a control code (lower order) setting on the following page
from H20 to H27.
f
Fmax
Fmin
3 − 500
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Elapsed value
Target value area
area
DT90348
DT90350
DT90349
DT90351
DT90352
DT90354
DT90353
DT90355
DT90356
DT90358
DT90357
DT90359
DT90360
DT90362
DT90361
DT90363
Near home input
Near
home
DT90052
DT90052
<bit4>
home input
t
home input
t
FPΣ/FP−X
home
input
X4
X4
X5
X5
X6
X6
X7
X7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp0Fp2Fp2shFp0rFrsFp10sh ... Show all