High−level Instructions
Flag conditions
・Error flag (R9007):
・Error flag (R9008):
Precautions during programming
The special data registers DT9054 to DT9056/DT90054 to DT90056 in which the values of the internal
calendar timer are stored, cannot be specified directly for D. To change the value of the internal calendar
timer, store the subtraction results in a separate memory area, and then use the F0 (MV) instruction to transfer
the value to DT9054 to DT9056/DT90054 to DT90056.
Data configuration for the internal calendar timer
FP2/FP2SH/FP10SH
DT90056
Years
Months
3 − 418
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Turns on and stays on when:
Turns on for an instant when:
− The area specified using the index modifier exceeds the limit.
− The data specified by S1 and S2 is not BCD data.
− The data specified by S1 is not the date/clock data.
− The data specified by S2 is not the time data.
− The specified data exceeds tha area.
DT90055
Days
Hours
DT90054
Minutes
Seconds