(3) For deceleration, the speed cannot be lower than the deceleration minimum speed.
For information on the deceleration minimum speed, refer to the special registers.
Assignment of control code (Specify with H constant)
10: Fixed
Control assignment
0: JOG
Control assignment 2
0: Type 0 (Without target values)
1: Type 1 (With target values)
0: Fixed
Output assignment
0: Pulse output
1: Calculation only
Movement direction
Type 0 (Without target values)
0: Forward
1: Reverse
Type 1 (With target values)
0: Incremental
1: Absolute
Output type assignment
0: CW/CCW
1: PLS+SIGN (Forward OFF/Reverse ON)
2: PLS+SIGN (Forward ON/Reverse OFF)
Output type 0 (without target values)
Mode selection
Operation mode
Forward
Reverse
Output type 1 (with target values)
Incremental <Relative control>
The pulses specified for the target value are output.
Mode selection
Target value
When positive
When negative
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
H
PLS+SIGN
CW/CCW
Forward OFF
Reverse ON
Pulse output when
Output from CW
direction output is off
Pulse output when
Output from CCW
direction output is on
PLS+SIGN
CW/CCW
Forward OFF
Reverse ON
Pulse output when
Output from CW
direction output is off
Pulse output when
Output from CCW
direction output is on
*As for the output assignment
When starting the instruction with th setting of "1: Calcula-
tion only", the pulse output is not performed.
When starting the instruction with the assignment of the
same channel and the same parameter after executing this
instruction once for a channel, it can be started at high
speed. (It is the same for the both cases of "Pulse output"
and "Calculation only".)
However, if a parameter othern than the parameter used for
the previous execution is specified, the high−speed startup
cannot be performed.
Note) The same parameter means that all the parameters
other than the output assignment are the same.
PLS+SIGN
Forward ON
Reverse OFF
Pulse output when
direction output is on
Pulse output when
direction output is off
PLS+SIGN
Forward ON
Reverse OFF
Pulse output when
direction output is on
Pulse output when
direction output is off
High−level Instructions
Elapsed value
Addition
Subtraction
Elapsed value
Addition
Subtraction
3 − 527