Asynchronous Interface
Figure 9–43. TMS320C6201/C6202/C6701 Ready Operation
Setup
CLKOUT1
CE
BE[3:0]
EA[21:2]
ED[31:0]
AOE
ARE
AWE
ARDY
9-58
TMS320C6201/C6202/C6701 Operation: If ARDY is low on the third ris-
ing edge of CLKOUT1 before the end of the programmed strobe period,
then the strobe period is extended by one CLKOUT1 cycle. For each sub-
sequent CLKOUT1 rising edge that ARDY is sampled low, the strobe peri-
od is extended by one CLKOUT1 cycle. Thus to effectively use CE to gen-
erate ARDY inactive with external logic the minimum of SETUP and
STROBE should be four.
The read cycle in Figure 9–43 illustrates ready operation for the
'C6201/C6202/C6701.
Programmed strobe
2
Ready sampled
Strobe
extended
5
BE
Address
Hold
CE hold
2
1
Data
latched
D
6