Switchport Mode Private-Vlan Trunk Secondary - Allied Telesis CentreCOM FS980M/9 Command Reference Manual

Centrecom fs980m series fast ethernet managed access switches alliedware plus version 5.4.7-0.x
Hide thumbs Also See for CentreCOM FS980M/9:
Table of Contents

Advertisement

VLAN C
OMMANDS
-
SWITCHPORT MODE PRIVATE
VLAN TRUNK SECONDARY
switchport mode private-vlan trunk
secondary
Overview
Use this command to enable a port in trunk mode to be a secondary port for
isolated VLANs.
Use the no variant of this command to remove a port in trunk mode as a secondary
port for isolated VLANs.
switchport mode private-vlan trunk secondary group <group-id>
Syntax
no switchport mode private-vlan trunk secondary
Default
By default, a port in trunk mode is disabled as a secondary port.
When a port in trunk mode is enabled to be a secondary port for isolated VLANs,
by default it will have a native VLAN of none(no native VLAN specified).
Mode
Interface Configuration
Usage
A port must be put in trunk mode with
the port is enabled as a secondary port in trunk mode.
To add VLANs to be trunked over the secondary port use the
allowed vlan
associated promiscuous port.
To configure the native VLAN for the secondary port, use the
native vlan
on the associated promiscuous port.
613-50157-01 Rev C
Parameter
<group-id>
command. These must be isolated VLANs and must exist on the
command. The native VLAN must be an isolated VLAN and must exist
Command Reference for FS980M Series
AlliedWare Plus™ Operating System - Version 5.4.7-0.x
Description
The group ID is a numeric value in the range 1 to 32 that is
used to associate a secondary port with its promiscuous port.
switchport mode trunk
command before
switchport trunk
switchport trunk
423

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents