Auth Timeout Connect-Timeout - Allied Telesis CentreCOM FS980M/9 Command Reference Manual

Centrecom fs980m series fast ethernet managed access switches alliedware plus version 5.4.7-0.x
Hide thumbs Also See for CentreCOM FS980M/9:
Table of Contents

Advertisement

A
C
UTHENTICATION
OMMANDS
-
AUTH TIMEOUT CONNECT
TIMEOUT

auth timeout connect-timeout

Overview
This command sets the connect-timeout period for the interface.
Use the no variant of this command to reset the connect-timeout period to the
default.
Syntax
auth timeout connect-timeout <1-65535>
no auth timeout connect-timeout
Default
The connect-timeout default is 30 seconds.
Mode
Interface Configuration for a static channel, a dynamic (LACP) channel group, or a
switch port; or Authentication Profile mode.
Usage
This command is used for MAC- and Web-Authentication. If the connect-timeout
has lapsed and the supplicant has the state connecting, then the supplicant is
deleted. When
we recommend you configure a longer connect-timeout period.
Examples
To set the connect-timeout period to 3600 seconds for port1.0.2, use the following
commands:
awplus#
awplus(config)#
awplus(config-if)#
To reset the connect-timeout period to the default (30 seconds) for port1.0.2, use
the following commands:
awplus#
awplus(config)#
awplus(config-if)#
To set the connect-timeout period to 3600 seconds for authentication profile
'student', use the commands:
awplus#
awplus(config)#
awplus(config-auth-profile)#
613-50157-01 Rev C
Parameter
Description
<1-65535>
Specifies the connect-timeout period (in seconds).
auth-web-server session-keep
configure terminal
interface port1.0.2
configure terminal
interface port1.0.2
configure terminal
auth profile student
Command Reference for FS980M Series
AlliedWare Plus™ Operating System - Version 5.4.7-0.x
or
auth timeout connect-timeout 3600
no auth timeout connect-timeout
auth timeout connect-timeout 3600
auth two-step
enableis enabled,
975

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents