4.4.1 Preparing the Ethernet Connection

4.4

Going Online with a SERVOPACK

4.4.1

Preparing the Ethernet Connection

When you connect a SERVOPACK and the Engineering Tool to Ethernet, you must set the IP
address of your computer. After you set the IP address for the computer, you will not need to
set it again for any future connections. Also, this setting is not necessary if you use a USB con-
nection for the SigmaWin+.
The procedure for setting the IP address of the computer is given below.
On the computer, select Control Panel − Network Connection − Local Area Connection
1.
− Properties from the Windows Start Menu.
2.
Double-click Internet Protocol (TCP/IP) in the list.
3.
Select the Use the following IP address Option, and enter the following data.
IP address =192.168.1.2
Subnet mask = 255.255.255.0
Important
4-46
Do not use the same IP address for both the MPE720 and the SERVOPACK.
The default IP address of the SERVOPACK is 192.168.1.1. Therefore, the IP address of the
MPE720 must be set to 192.168.1.
(where
is a value between 2 and 254).