Using Sgda Servopack With High Voltage Line - YASKAWA SGM series User Manual

Ac servomotors and drivers
Hide thumbs Also See for SGM series:
Table of Contents

Advertisement

2) Connect cables of the same color to each other as shown in the table below. Note that
wiring for incremental and absolute encoders is different.
Signal
Name
PG5V
PG0V
FG
PA
PA
*
PB
PB
*
PC
PC
*
PS
PS
*
RESET
BAT
BAT0

3.8.7 Using SGDA Servopack with High Voltage Line

1) SGDA Servopacks are divided into single-phase 200 V and single-phase 100 V types
according to supply voltage.
If, however, three-phase 400 VAC class (400 V, 440 V) power supply must be used, pre-
pare the following power transformer (for single-phase).
Color and Wire Size of
Cable with Connectors
Red
AWG22
Black
AWG22
Green/Yellow
AWG22
Blue
AWG26
White/Blue
AWG26
Yellow
AWG26
White/Yellow
AWG26
Green
AWG26
White/Green
AWG26
Violet
AWG26
White/Green
AWG26
White/Gray
AWG26
Orange
AWG26
White/Orange
AWG26
<Primary side>
1) 400 or 440 VAC
2) 400 or 440 VAC
Color and Wire Size of
50-meter Extension
Cable (DP8409179)
Red
AWG16
Black
AWG16
Green/Yellow
AWG16
Blue
AWG26
White/Blue
AWG26
Yellow
AWG26
White/Yellow
AWG26
Green
AWG26
White/Green
AWG26
Purple
AWG26
White/Green
AWG26
White/Gray
AWG26
Orange
AWG26
White/Orange
AWG26
<Secondary side>
200 VAC
100 VAC
3.8 Special Wiring