YASKAWA SGD7C-***AMAA*** Product Manual page 25

Ac servo drive
Table of Contents

Advertisement

 Discharge all static electricity from your body before you operate any of the buttons or switches
inside the front cover of the SERVOPACK.
There is a risk of equipment damage.
 Troubleshooting Precautions
 If the safety device (molded-case circuit breaker or fuse) installed in the power supply line oper-
ates, remove the cause before you supply power to the SERVOPACK again. If necessary, repair
or replace the SERVOPACK, check the wiring, and remove the factor that caused the safety
device to operate.
There is a risk of fire, electric shock, or injury.
 The SERVOPACK may suddenly restart when the power supply is recovered after a momentary
power interruption. Design the machine to ensure human safety when operation restarts.
There is a risk of injury.
 When an alarm occurs, remove the cause of the alarm and ensure safety. Then reset the alarm
or turn the power supply OFF and ON again to restart operation.
There is a risk of injury or machine damage.
 If the Servo ON signal is input to the SERVOPACK and an alarm is reset, the Servomotor may
suddenly restart operation. Confirm that the servo is OFF and ensure safety before you reset an
alarm.
There is a risk of injury or machine damage.
 Always insert a magnetic contactor in the line between the main circuit power supply and the
main circuit power supply terminals on the SERVOPACK so that the power supply can be shut
OFF at the main circuit power supply.
If a magnetic contactor is not connected when the SERVOPACK fails, a large current may flow con-
tinuously, possibly resulting in fire.
 If an alarm occurs, shut OFF the main circuit power supply.
There is a risk of fire due to a regenerative resistor overheating as the result of regenerative transis-
tor failure.
 Install an earth leakage breaker against overloads and short-circuiting or install a molded-case
circuit breaker combined with an earth leakage breaker against ground faults.
There is a risk of SERVOPACK failure or fire if a ground fault occurs.
 The holding brake on a Servomotor will not ensure safety if there is the possibility that an exter-
nal force (such as gravity) may move the current position and create a hazardous situation when
power is interrupted or an error occurs. If an external force may cause movement, install an
external braking mechanism that ensures safety.
 Disposal Precautions
 When disposing of the product, treat it as ordinary industrial waste. However, local ordinances
and national laws must be observed. Implement all labeling and warnings for the final product
as required.