12.8 Counter Function Module
12.8.3 Setting Up the Counter Function Module
No.
Number of Digits Below
09
Decimal Point
Travel Distance per
10
Machine Rotation
11
Encoder Gear Ratio
12
Machine Gear Ratio
Maximum Value of
Rotary Counter (Infinite
13
Length Axis Reset Posi-
tion (POSMAX))
Encoder Resolution (Pre
Quadrature) (Number of
14
Pulses Per Encoder
Rotation (before Multipli-
cation))
Detection of A/B-pulse
15
Disconnection
16
C Phase Filter Setting
*1.
Refer to the following section for details.
*2.
Refer to the following section for details.
*3.
Refer to the following section for details.
*4.
Refer to the following section for details.
When fixed parameter No. 8 (Reference Unit Selection) parameter is set to Pulse, the settings for fixed parame-
*5.
ters No. 10 to 12 are ignored.
Important
12-64
Name
Set the number of digits below the decimal point
for the minimum reference unit
to 5.
For example, to set the minimum reference unit to
1 μm (10
ence Unit Selection) to mm, and set fixed parame-
ter No. 09 (Number of Digits Below Decimal Point)
to 3.
Set the load travel distance per load shaft rotation
to a value from 1 to 2,147,483,647 (reference
*4, *5
units).
Set the value of m when the load shaft rotates n
*4, *5
times in response to m encoder shaft rotations to a
value from 1 to 65,535.
Set the value of n when the load shaft rotates n
*4, *5
times in response to m encoder shaft rotations to a
value from 1 to 65,535.
When an infinite-length axis is selected with fixed
parameter No. 7 (Axis Type Selection), set the posi-
tion at which to reset every rotation to a value from
*3
1 to 2,147,483,647.
Set the number of pulses per encoder rotation to a
value from 1 to 2,147,483,647 (pulses/rev).
Enable or disable disconnection detection for
phases A and B.
Set the phase-C pulse filter to a value from 0 to
65,535 (μs).
Pulse Counting Method on page 12-52
Coincidence Detection and Coincidence Interrupts on page 12-56
Axis Type on page 12-58
12.8.2 Electronic Gear on page 12-58
After you change the synchronized scan, you must save the settings to flash memory, and then
restart the SERVOPACK.
Description and Selections
*4
to a value from 0
-3
mm), set fixed parameter No. 8 (Refer-
Continued from previous page.
Default Set-
Size
ting
1 word
3
2 words
10,000
1 word
1
1 word
1
2 words
360,000
2 words
2,048
1 word
Disabled
1 word
0