YASKAWA SGD7C-***AMAA*** Product Manual page 590

Ac servo drive
Table of Contents

Advertisement

12.1 Data Logging
12.1.5 Analyzing Log Data
12-16
The following example shows how the register data is given for the settings and con-
Example
ditions listed below.
File Details to Output
• Data No. and DATE/TIME are selected.
Target Register to Log
• MW00000
Status
• Data No.: 000001
• DATE/TIME: 2011/06/23 18:02:19
• Value of MW00000 register: 100
Displayed Value
The data is stored in little endian as shown below.
01 00 00 00 00 00 00 00 11 00 23 06 02 18 19 00 64 00
MW00000 = 100
DATE/TIME =
2011/06/23 18:02:19
Data No. = 1

Advertisement