8.4.2
Operating Procedure
The tuning-less function is enabled in the default settings. No specific procedure is required.
You can use the following parameter to enable or disable the tuning-less function.
Parameter
n.
n.
(default setting)
Pn170
n.
(default setting)
n.
When you enable the tuning-less function, you can select the tuning-less type. Normally, set
Pn14F to n.
If compatibility with previous models is required, set Pn14F to n.
or n.
1
(Use tuning-less type 2).
Parameter
n.
n.
Pn14F
n.
(default setting)
Tuning-less Level Settings
If vibration or other problems occur, change the tuning-less levels. To change the tuning-less
levels, use the SigmaWin+.
Preparations
Always check the following before you set the tuning-less levels.
• The tuning-less function must be enabled (Pn170 = n.
• The test without a motor function must be disabled (Pn00C = n.
Procedure
Use the following procedure to set the tuning-less levels.
In addition to the following procedure, you can also set the parameters directly. Refer to
Related Parameters, below, for the parameters to set.
1.
Click the
maWin+.
2.
Select Response Level Setting in the Menu Dialog Box.
The Response Level Setting Dialog Box will be displayed.
0
Disable tuning-less function.
1
Enable tuning-less function.
0
Use for speed control.
Use for speed control and use host con-
1
troller for position control.
2
(Use tuning-less type 3) (default setting).
0
Use tuning-less type 1.
Use tuning-less type 2. (The noise level is
1
improved more than with tuning-less type
1.)
2
Use tuning-less type 3.
Servo Drive Button in the workspace of the Main Window of the Sig-
Meaning
Meaning
1).
8.4 Tuning-less Function
8.4.2 Operating Procedure
When Enabled
Classification
After restart
Setup
0
(Use tuning-less type 1)
When Enabled
Classification
After restart
Tuning
0).
8
8-13