9.4 Monitoring Product Life

9.4.2 Operating Procedure

9.4.2
Operating Procedure
Use the following procedure to display the installation environment and service life prediction
monitor dialog boxes.
1.
Click the
maWin+.
2.
Select Life Monitor in the Menu Dialog Box.
The Life Monitor Dialog Box will be displayed.
9.4.3

Preventative Maintenance

You can use the following functions for preventative maintenance.
• Preventative maintenance warnings
• /PM (Preventative Maintenance Output) signal
The SERVOPACK can notify the host controller when it is time to replace any of the main parts.
Preventative Maintenance Warning
An A.9b0 warning (Preventative Maintenance Warning) is detected when any of the following
service life prediction values drops to 10% or less: SERVOPACK built-in fan life, capacitor life,
inrush current limiting circuit life, and dynamic brake circuit life. You can change the setting of
Pn00F = n.
Pn00F
9-10
Servo Drive Button in the workspace of the Main Window of the Sig-

X to enable or disable these warnings.
Parameter

n.
0
Do not detect preventative maintenance
(default setting)
warnings.

n.
1
Detect preventative maintenance warnings.
A value of 100% indicates that the SERVOPACK has
not yet been used. The percentage decreases as the
SERVOPACK is used and reaches 0% when it is time
to replace the SERVOPACK.
Meaning
When Enabled