9.3.2

Operating Procedure

This section describes how to trace data with the SigmaWin+.
Refer to the following manual for detailed operating procedures for the SigmaWin+.
AC Servo Drive Engineering Tool SigmaWin+ Operation Manual (Manual No.: SIET S800001 34)
1.
Click the
maWin+.
2.
Select Trace in the Menu Dialog Box.
The Trace Dialog Box will be displayed.
Trace Objects
You can trace the following items.
• Data Tracing
• Torque Reference
• Feedback Speed
• Reference Speed
• Position Reference Speed
• Position Error (Deviation)
• Position Amplifier Error
(Deviation)
9.3 Monitoring Machine Operation Status and Signal Waveforms
Servo Drive Button in the workspace of the Main Window of the Sig-
Trace Objects
• Speed Feedforward
• Torque Feedforward
• Effective (Active) Gain
• Main Circuit DC Voltage
9.3.2 Operating Procedure
Click this button to display the Trace Setting
Dialog Box shown below, and set the data to
trace and the trace conditions.