YASKAWA SGD7C-***AMAA*** Product Manual page 397

Ac servo drive
Table of Contents

Advertisement

7.8 Monitoring Machine Operation
7.8.2 Alarm Monitor
 Status
If an alarm or a warning occurs, the alarm or warning status will be shown on the Alarm Monitor
Tab Page in the following way:
Displaying Alarms and Warnings
If an alarm or a warning occurs, double-click the axis where the alarm or warning occurred to
display the Alarm/Warning Dialog Box.
No.
Troubleshooting Alarms and Warnings
When an alarm occurs, the status will change to
tus will change to
Click the status indicator to display the Alarm/Warning Dialog Box to see details on the alarm
or warning.
This section uses a SERVOPACK Communications Error as an example to describe what to do
when an alarm or warning occurs.
1.
Click the status indicator in the Alarm Monitor Tab Page.
The Alarm/Warning Dialog Box will be displayed.
7-88
Icon
Name
No Alarm
Alarm Occurred
Warning Occurred
Item
Axis name
Alarm Clear
Help
Refresh
Alarms/warnings display
Close
No alarm or warning has occurred.
An alarm has occurred.
A warning has occurred.
This row displays the name of the axis. The display takes the fol-
lowing format: Assigned axis number: Comment: Type.
This button clears the alarm.
This button displays the manual related to the alarm that
occurred.
This button updates the contents of the Alarm/Warning Dialog
Box.
Displays the parameter name, the bit number, and the status.
This area shows the alarm and warning information bit by bit for
each Motion Control Function Module.
This button closes the Alarm/Warning Dialog Box.
.
Function
Function
. When a warning occurs, the sta-