Select the storage location.
Selection
In the built-in
RAM disc
USB memory
FTP server
Select the file format.
Selection
CSV
Binary
Select the file information to output.
The selected items are appended to the header information in the output file.
Selection
Data No.
DATE/TIME
Registered register
name
Program
Sampling period
Enter the number of data items to output.
Enter the number of lines to write to a single file.
• Setting range: 1 to 32,767
Set the file name.
• Characters allowed: Alphabet A to Z and a to z, numerals 0 to 9, the minus sign, and
the underscore.
• Maximum string length: 32 characters
1. A five-digit index number that starts from 00001 is automatically added to the end
Information
of the specified file name.
2. Click the Default Button to enter "logging".
Set the name of the folder to create.
• Characters allowed: Alphabet A to Z and a to z, numerals 0 to 9, the minus sign, and
the underscore.
• Maximum string length: 32 characters*
*
If you select Year/Month/Day/Hour (YYYYMMDDHH) in step
If this box is left blank, a folder will not be created. Instead, the file will be created in
Information
the root directory of the specified storage location.
Writes the sampled data to the built-in RAM disk in the CPU.
Writes the sampled data to the USB memory device in the CPU.
Writes the sampled data to the FTP server connected to Ethernet.
This file format can be opened in general-purpose applications such as Excel
and Notepad.
This file format is not affected by the range of character codes. Binary files
are smaller than CSV files, so they can be written faster and with less over-
head on the scan.
The number that is assigned to the sampled data
The date and time down to the seconds when the data was sampled
Make sure to set the calendar in advance. Refer to the following section for
details.
12.4 Calendar on page 12-30
Name of the register
Program names
The frequency at which data was sampled
Set this in the Sampling and Trigger Dialog Box that is explained later in this
section.
12.1 Data Logging
12.1.1 Operating Procedure
Description
Description
Description
, the maximum string length will be 31.