8.3.4

Finisher firmware (MJ-1025)

Important:
Be sure to shut down the equipment before installing and removing the download jig.
Do not shut down the equipment during the update. The data could be damaged and not be
operated properly.
[A] Update Procedure
(1)
Install the ROM to the download jig.
Make sure the direction is correct.
(2)
Press the [ON/OFF] button on the control panel to shut down the equipment and turn the power
OFF using the main power switch.
(3)
Take off the finisher rear cover.
* Connect the finisher interface cable with the equipment after removing the finisher rear cover.
(4)
Connect the download jig with the jig connector on the finisher control PC board.
© 2009 TOSHIBA TEC CORPORATION All rights reserved
Finisher rear cover
Fig. 8-31
Connector
Fig. 8-32
8 - 33