11.4.3
Finisher firmware (MJ-1103/1104)
Important:
•
Be sure to shut down the equipment before installing and removing the download jig.
•
Do not shut down the equipment during the update. The data could be damaged and not be
able to be operated properly.
[A] Update Procedure
(1)
Install the ROM to the download jig (K-PWA-DLM-320).
Make sure the direction is correct.
(2)
Press the [ON/OFF] button on the control panel to shut down the equipment.
(3)
Remove 2 screws and take off the board access cover.
(4)
Connect the download jig with the jig connector (CN28) on the Finisher control board.
(5)
Press the [ON/OFF] button while simultaneously holding down the [0] and [8] buttons.
Updating starts and the LED on the download jig lights.
(6)
When the update completes normally, the LED on the download jig starts blinking.
The LED on the download jig starts blinking approx. 12 seconds after the update started.
It is assumed that the update has failed if the LED does not start blinking even after 20 seconds
have elapsed.
In this case, turn the power OFF and check the following items.
Then, clear the problem and restart updating from the beginning.
•
Is the downloading jig connected properly?
•
Is the ROM attached to the downloading jig properly?
•
Has the update data been written correctly to the ROM on the jig?
•
Is the download jig or the equipment damaged?
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
Board access cover
Fig.11-31
Download jig
Fig.11-32
11 - 39
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
FIRMWARE UPDATING