Related commands: schedule reboot at, schedule reboot delay.
Examples
# Display the information about scheduled reboot.
<Sysname> display schedule reboot
System will reboot at 16:00:00 2002/11/1 (in 2 hours and 5 minutes).
display transceiver alarm interface
Syntax
display transceiver alarm interface [ interface-type interface-number ]
View
Any view
Parameters
interface-type interface-number: Interface type and interface number.
Description
Use the display transceiver alarm interface command to display the current alarm information of a
single or all transceivers.
If no error occurs, None is displayed.
Table 3-7
shows the alarm information that may occur for the four types of transceivers.
Table 3-7 Description on the fields of display transceiver alarm interface
GBIC/SFP
RX loss of signal
RX power high
RX power low
TX fault
TX bias high
TX bias low
TX power high
TX power low
Temp high
Temp low
Voltage high
Voltage low
Transceiver info I/O error
Transceiver info checksum error
Field
Remarks
RX signal is lost.
RX power is high.
RX power is low.
TX fault
TX bias current is high.
TX bias current is low.
TX power is high.
TX power is low.
Temperature is high.
Temperature is low.
Voltage is high.
Voltage is low.
Transceiver information read and write error
Transceiver information checksum error
3-8
Need help?
Do you have a question about the s3600 series and is the answer not in the manual?
Questions and answers