Probe-Failtimes - H3C s3600 series Command Manual

Hide thumbs Also See for s3600 series:
Table of Contents

Advertisement

Related commands: username, ftp-operation.
To perform an FTP test successfully, the configured password must be consistent with the FTP
user password configured on the server.
This command applies to FTP tests only.
Examples
# Set the password for logging into the FTP server as hwping in an FTP test.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] hwping administrator ftp
[Sysname-hwping-administrator-ftp] test-type ftp
[Sysname-hwping-administrator-ftp] password hwping

probe-failtimes

Syntax
probe-failtimes times
undo probe-failtimes
View
HWPing test group view
Parameters
times: Number of consecutive failed probes, in the range of 1 to 15.
Description
Use the probe-failtimes command to configure the number of consecutive times the probe fails before
the switch sends out a trap message.
Use the undo probe-failtimes command to restore the default.
By default, the switch sends a trap about probe failure each time when a probe fails.
Examples
# Configure the switch to send a trap after the probe in an ICMP test fails for three consecutive times.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] hwping administrator icmp
[Sysname-hwping-administrator-icmp] test-type icmp
[Sysname-hwping-administrator-icmp] probe-failtimes 3
1-19