Canon imageRUNNER ADVANCE C350 series Service Manual page 617

Table of Contents

Advertisement

Error Code
Error Code Details
Error
Detail
Location
Item
code
Code
E001 A001 05
Title
Fixing Main Thermistor high temperature detection error
Detection
The Fixing Main Thermistor detected 265 deg C or higher for 0.1
description
sec or longer.
Remedy
[Related parts]
- Fixing Assembly (Unit of replacement: Fixing Assembly)
- Low-voltage Power Supply PCB (UN01) (Unit of replacement:
POWER SUPPLY ASSEMBLY)
- DC Controller PCB (UN04) (Unit of replacement: DC
CONTROLLER PCB ASSEMBLY)
- Harness between the Fixing Drawer (DR01/J5401) and
the Low-voltage Power Supply PCB (UN01/J302) (Unit of
replacement: INTERLOCK ASSEMBLY)
- Harness between the Low-voltage Power Supply PCB (UN01/
J315 and J322) and the DC Controller PCB (UN04/J20 and
J22) (Unit of replacement: CABLE, POWER SUPPLY)
- Harness between the Fixing Drawer (DR01/J5401) and the DC
Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK
ASSEMBLY)
[Points to note at work] When checking the harness/cable or
connector, perform the following work.
1. Disconnect and then connect the connector to check that
there is no bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
[Remedy] Check/replace the related parts.
[Reference] Before replacing the DC Controller PCB, back up
the service mode data (approx. 2 min) and restore the backup
data after the replacement so the data may be able to be
protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM>
DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM>
DSRAMRES
7
Error•Jam•Alarm > Error Code > Error Code Details
Description
7
Error•Jam•Alarm > Error Code > Error Code Details
Error
Detail
Location
Item
code
Code
E001 A002 05
Title
Fixing Sub Thermistor (Front) high temperature detection error
Detection
The Fixing Sub Thermistor (Front) detected 290 deg C or higher
description
for 0.1 sec or longer.
Remedy
[Related parts]
- Fixing Assembly (Unit of replacement: Fixing Assembly)
- Low-voltage Power Supply PCB (UN01) (Unit of replacement:
POWER SUPPLY ASSEMBLY)
- DC Controller PCB (UN04) (Unit of replacement: DC
CONTROLLER PCB ASSEMBLY)
- Harness between the Fixing Drawer (DR01/J5401) and
the Low-voltage Power Supply PCB (UN01/J302) (Unit of
replacement: INTERLOCK ASSEMBLY)
- Harness between the Low-voltage Power Supply PCB (UN01/
J315 and J322) and the DC Controller PCB (UN04/J20 and
J22) (Unit of replacement: CABLE, POWER SUPPLY)
- Harness between the Fixing Drawer (DR01/J5401) and the DC
Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK
ASSEMBLY)
[Points to note at work] When checking the harness/cable or
connector, perform the following work.
1. Disconnect and then connect the connector to check that
there is no bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
[Remedy] Check/replace the related parts.
[Reference] Before replacing the DC Controller PCB, back up
the service mode data (approx. 2 min) and restore the backup
data after the replacement so the data may be able to be
protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM>
DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM>
DSRAMRES
7-3
Description
7-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents