Canon imageRUNNER ADVANCE C350 series Service Manual page 932

Table of Contents

Advertisement

COPIER> OPTION> CUSTOM
FAN-POST
Dup Cool Fan oprtn time:aftr 1-sided fd
Lv.2 Details
To set the operation time of the Duplex Cooling Fan after performing
1-sided feeding.
As the value is larger, water droplets occurred on the Feed Path
during 1-sided printing can be removed, but downtime is increased.
Use case
When an image failure (droplet mark) occurs due to condensation
after feeding moistened paper
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Downtime occurs.
Display/adj/set range
0 to 3
0: OFF, 1: 15 seconds, 2: 30 seconds, 3: 60 seconds
Default value
0
RDEV-SP1
RCON device special settings 1
Lv.2 Details
To execute the device special setting.
Use case
For customization
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Use this mode only when specific instructions are given.
Display/adj/set range
00000000 to 11111111
Default value
0
RDEV-SP2
RCON device special settings 2
Lv.2 Details
To execute the device special setting.
Use case
For customization
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Use this mode only when specific instructions are given.
Display/adj/set range
00000000 to 11111111
Default value
0
RDEV-SP3
RCON device special settings 3
Lv.2 Details
To execute the device special setting.
Use case
For customization
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Use this mode only when specific instructions are given.
Display/adj/set range
00000000 to 11111111
Default value
0
RDEV-SP4
RCON device special settings 4
Lv.2 Details
To execute the device special setting.
Use case
For customization
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Use this mode only when specific instructions are given.
Display/adj/set range
00000000 to 11111111
Default value
0
8
Service Mode > COPIER > OPTION > CUSTOM
8
Service Mode > COPIER > OPTION > CUSTOM
COPIER> OPTION> CUSTOM
RDEV-SP5
RCON device special settings 5
Lv.2 Details
To execute the device special setting.
Use case
For customization
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Use this mode only when specific instructions are given.
Display/adj/set range
00000000 to 11111111
Default value
0
RDEV-SP6
RCON device special settings 6
Lv.2 Details
To execute the device special setting.
Use case
For customization
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Use this mode only when specific instructions are given.
Display/adj/set range
00000000 to 11111111
Default value
0
RDEV-SP7
RCON device special settings 7
Lv.2 Details
To execute the device special setting.
Use case
For customization
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Use this mode only when specific instructions are given.
Display/adj/set range
00000000 to 11111111
Default value
0
RDEV-SP8
RCON device special settings 8
Lv.2 Details
To execute the device special setting.
Use case
For customization
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Use this mode only when specific instructions are given.
Display/adj/set range
00000000 to 11111111
Default value
0
MEAO-JBO
ON/OFF of MEAP appli continuous reading
Lv.2 Details
To set whether to receive continuous reading jobs from MEAP
application.
Use case
When performing continuous reading from MEAP application
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Use this mode only when specific instructions are given.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Supplement/memo